Showing results: 16 - 30 of 257 items found.
-
-
21-8569-00 -
LANTAC Techtronics Co. LTD
Open / Short / Misswiring test?BNC / RJ45 each pin connected display?No wire or termination?Isolation Resistances 50K ohms test
-
N1125A -
Keysight Technologies
The x1149 is a tool for engineers to perform structural test such as opens and shorts tests on their PCBAs. It also performs In-System Programming for devices such as FPGAs and CPLDs.
-
778572-14 -
NI
7-Channel, 40 A PXI Signal Insertion Switch Module—The PXI‑2514 fault insertion unit (FIU) is designed for hardware‑in‑the‑loop (HIL) applications and electronic reliability tests. Each module has a set of feedthrough channels that you can open or short to one or more fault buses. You can use this architecture to simulate open or interrupted connections as well as shorts between pins, shorts to battery voltages, and shorts to ground on a per-channel basis. When controlled with the LabVIEW Real-Time Module, the PXI‑2514 is ideal for validating the integrity of control systems including engine control units (ECUs) and full authority digital engine controls
-
778572-12 -
NI
7-Channel, 10 A PXI Signal Insertion Switch Module—The PXI‑2512 fault insertion unit (FIU) is designed for hardware‑in‑the‑loop (HIL) applications and electronic reliability tests. Each module has a set of feedthrough channels that you can open or short to one or more fault buses. You can use this architecture to simulate open or interrupted connections as well as shorts between pins, shorts to battery voltages, and shorts to ground on a per-channel basis. When controlled with the LabVIEW Real-Time Module, the PXI‑2512 is ideal for validating the integrity of control systems including engine control units (ECUs) and full authority digital engine controls
-
778572-10 -
NI
68-Channel, 2 A PXI Signal Insertion Switch Module—The PXI‑2510 fault insertion unit (FIU) is designed for hardware‑in‑the‑loop (HIL) applications and electronic reliability tests. Each module has a set of feedthrough channels that you can open or short to one or more fault buses. You can use this architecture to simulate open or interrupted connections as well as shorts between pins, shorts to battery voltages, and shorts to ground on a per-channel basis. When controlled with the LabVIEW Real-Time Module, the PXI‑2510 is ideal for validating the integrity of control systems including engine control units (ECUs) and full authority digital engine controls
-
MT-7051N -
Prokit's Industries Co., Ltd.
Tests RJ45 TIA568A/B (AT&T 258A), 10 Base-T, Token ring, RJ-11/ RJ-12 USOC and Coaxial BNC cable.Automatically check cable for continuity, short, open and crossed wire pairs.Coaxial cable port indentifies cable conditions including shorts, shield opens and center conductor breaks.Main unit and remote allow one person testing.Power source: DC 9V BatteryDimension: 102x106x28 (mm)Cable not include
-
CAL-SMA-6B -
MegiQ BV
The CAL-SMA-6B Basic calibration kit provides the elements for performing Open–Short–Load and Through calibrations for one and two port VNA measurements.
-
STM-8 -
The Siemon Company
The STM-8 is an economical and versatile hand-held tester designed for the testing of UTP and screened cable for opens, shorts, reversals, miswires, split pairs and cable length.
-
7411 -
Peaceful Thriving Enterprise Co Ltd
Find short and open circuits quickly and easily in DC circuits from 6-42V. Designed to identify and trace wires or cables without damaging the insulation.
-
Psiber Data Systems
The CableTool uses TDR (Time Domain Reflectometry) technology to quickly identify an open or a short from 0 to 2,500 feet within a foot of the fault.
-
WF 3154 C-Series -
WireFlow AB
The WF 3154 from WireFlow is a 4-channel Fault Injection Module for Compact RIO. Each channel provide three solid state relays that can be used to create electrical fault conditions like: Open circuit, Short circuit to battery, Short circuit to ground.
-
11930B -
Keysight Technologies
The Keysight 11930B limiter provides input protection for a variety of RF and microwave instrumentation. Failure mode for the limiter is either an open circuit or a short circuit to ground, thereby protecting the instrument from damage. The Keysight 11930B provides the same protection to spectrum analyzers and sources. At even greater power levels, failure mode for limiter is either an open circuit or a short circuit to ground, thereby protecting the instrument from damage.
-
780587-12 -
NI
PXIe, 7-Channel, 10 A PXI Signal Insertion Switch Module—The PXIe‑2512 fault insertion unit (FIU) is designed for hardware‑in‑the‑loop (HIL) applications and electronic reliability tests. Each module has a set of feedthrough channels that you can open or short to one or more fault buses. You can use this architecture to simulate open or interrupted connections as well as shorts between pins, shorts to battery voltages, and shorts to ground on a per-channel basis. When controlled with the LabVIEW Real-Time Module, the PXIe‑2512 is ideal for validating the integrity of control systems including engine control units (ECUs) and full authority digital engine controls (FADECs).
-
780587-14 -
NI
PXIe, 7-Channel, 40 A PXI Signal Insertion Switch Module—The PXIe‑2514 fault insertion unit (FIU) is designed for hardware‑in‑the‑loop (HIL) applications and electronic reliability tests. Each module has a set of feedthrough channels that you can open or short to one or more fault buses. You can use this architecture to simulate open or interrupted connections as well as shorts between pins, shorts to battery voltages, and shorts to ground on a per-channel basis. When controlled with the LabVIEW Real-Time Module, the PXIe‑2514 is ideal for validating the integrity of control systems including engine control units (ECUs) and full authority digital engine controls (FADECs).